Rockwell Automation Publication 6181X-UM001C-EN-P - July 2015 59
Specifications Appendix A
Table 5 - Environmental Specifications
Attribute 6181X-NPXPDC, 6181X-NPW7DC, 6181X-12TPXPDC, 6181X-12TPW7DC
Temperature, operating
Non-display models
Display models
(1)
(1) See Installation Guidelines on page 21 for more information about temperature guidelines.
-20…70 °C (-4…158 °F)
-20…55 °C (-4…131 °F), display side
-20…70 °C (-4…158 °F), back side
Temperature, nonoperating -30…80 °C (-22…176 °F)
Relative humidity 10…90% without condensation
Altitude, operating 2,000 m (6,561 ft)
Altitude, nonoperating 12,000 m (40,000 ft)
Shock, operating
(2)
(2) Applies only to panel-mounted computers.
15 g (1/2 sine, 11 ms)
Shock, nonoperating
(3)
30 g (1/2 sine, 11 ms)
Vibration, operating
(3)
0.012 in p-p (10…57 Hz); 2 g peak (57…640 Hz)
Enclosure ratings
(3)
Display models
(3) Ratings apply when computer is properly mounted on a flat surface of an equivalent type enclosure.
Rated UL Type 4X and 12, also rated IP66 as Classified by UL
Table 6 - Certifications
Attribute
(1)
6181X-NPXPDC, 6181X-NPW7DC, 6181X-12TPXPDC, 6181X-12TPW7DC
cULus UL/c-UL Listed as Information Technology Equipment for Use in Hazardous Locations per
standards ANSI/ISA 12.12.01, CSA C22.2 No. 213
Enclosure Type ratings per UL50 and CSA C22.2 No. 94.2-07 Enclosure ingress protection
Classified by UL per IEC 60529
IECEx IEC60079-0 2011
IEC60079-15 2010
IEC60079-31 2013
IECEx PRE 15.0040X (for display computers)
IECEx PRE 15.0041U (for non-display computers)
ATEX EN60079-0 2012
EN60079-15 2010
EN60079-31 2014
Presafe 15 ATEX 6736X (for display computers)
Presafe 15 ATEX 6737U (for non-display computers)
CE EMC 2004/108/EC
• Immunity standards: EN55024
• Emission standards: EN55022 Class A
ATEX 94/9/EC
Waste Electrical and Electronic Equipment (WEEE) 2002/96/EC
Metric Directive 80/181-EEC
EU Battery Directive 2006/66/EC
Low Voltage Directive: LVD 2006/95/EC
• EN 60950-1