xx237 Ch1 SendCurr Err Configurable P39
[FB1 Loss Cfg]
Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Transmitter current critical (dirt, broken transmitter)
xx238 Ch1 EncTemp Err Configurable P39
[FB1 Loss Cfg]
Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Encoder temperature critical
xx239 Ch1 Speed Err Configurable P39
[FB1 Loss Cfg]
Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Speed too high, no position formation possible
xx240 Ch1 General Err Configurable P39
[FB1 Loss Cfg]
Error reported by an Encoder on Channel 1 with BiSS Interface - An error
bit of the BiSS Single Cycle Data is set
xx246 Ch1 LED Curr Err Configurable P39
[FB1 Loss Cfg]
Error reported by an Encoder on Channel 1 with BiSS Interface - LED
current out of control range
xx247 Ch1 ExMulTurnErr Configurable P39
[FB1 Loss Cfg]
Error reported by an Encoder on Channel 1 with BiSS Interface - External
multi-turn error
xx248 Ch1 PsnCode Err Configurable P39
[FB1 Loss Cfg]
Error reported by an Encoder on Channel 1 with BiSS Interface - Position
code error (single step error)
xx249 Ch1 Config Err Configurable P39
[FB1 Loss Cfg]
Error reported by an Encoder on Channel 1 with BiSS Interface - failure
configuring interface
xx250 Ch1 PsnVal Err Configurable P39
[FB1 Loss Cfg]
Error reported by an Encoder on Channel 1 with BiSS Interface - Position
data not valid
xx251 Ch1 SerialComErr Configurable P39
[FB1 Loss Cfg]
Error reported by an Encoder on Channel 1 with BiSS Interface - Serial
interface failure
xx252 Ch1 Ext Failure Configurable P39
[FB1 Loss Cfg]
Error reported by an Encoder on Channel 1 with BiSS Interface - External
failure over NERR
xx253 Ch1 Temp Exc Err Configurable P39
[FB1 Loss Cfg]
Error reported by an Encoder on Channel 1 with BiSS Interface -
Temperature out of defined range
xx256 Ch1 OutOfRailErr Configurable P39
[FB1 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 1 - Rail is no longer
present between the read head
xx260 Ch1 Read Head 1 Configurable P39
[FB1 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 1 - Indicates that the
read head must be cleaned or installed correctly
xx261 Ch1 Read Head 2 Configurable P39
[FB1 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 1 - Indicates that the
read head must be cleaned or installed correctly
xx262 Ch1 RAM Error Configurable P39
[FB1 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 1 - Indicates a RAM
error. Reading head must be repaired
xx263 Ch1 EPROM Error Configurable P39
[FB1 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 1 - Indicates an
EPROM error. Reading head must be repaired
xx264 Ch1 ROM Error Configurable P39
[FB1 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 1 - Indicates a ROM
error. Reading head must be repaired
xx
266 Ch1 No Position Configurable P39
[FB1 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 1 - Indicates that no
position value was available - only possible following powerup or reset
xx281 Ch1 Msg Cheksum Configurable P39
[FB1 Loss Cfg]
Indicates that the option card has detected a serial communications
checksum error while attempting to communicate with the encoder on
channel 1.
xx282 Ch1 Timeout Configurable P39
[FB1 Loss Cfg]
Indicates that the option card has detected a serial communications
timeout error while attempting to communicate with the encoder on
channel 1.
xx283 Ch1 Comm Configurable P39
[FB1 Loss Cfg]
Indicates that the option card has detected a serial communications
error (other than checksum or timeout) while attempting to
communicate with the encoder on channel 1.
xx284 Ch1 Diagnostic Configurable P39
[FB1 Loss Cfg]
Indicates that the option card has detected a powerup diagnostic test
failure for encoder channel 1.
xx285 Ch1 SpplyVltgRng Configurable P39
[FB1 Loss Cfg]
Indicates that the voltage source to the encoder 1 is out of range.
Event
No.
(1)
Fault/Alarm Text Type Fault
Action
Configuration Param Auto
Reset
Description

Table of Contents

Other manuals for Allen-Bradley PowerFlex 750 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PowerFlex 750 Series and is the answer not in the manual?

Allen-Bradley PowerFlex 750 Series Specifications

General IconGeneral
BrandAllen-Bradley
ModelPowerFlex 750 Series
CategoryController
LanguageEnglish

Related product manuals