NeXGen Gilbarco/Bennett - Installation and Start Up Guide
Copyright 2018 by Allied Electronics, Inc.
October 18, 2018 Page
II
Table of Contents
1 General Information.............................................................................................................. 1-1
1.1 Installation Environment ..................................................................................................... 1-1
1.2 Wiring................................................................................................................................. 1-1
1.2.1 Field Wiring.................................................................................................................1-1
1.2.2 Internal Wiring............................................................................................................. 1-1
1.2.2.1 Introduction ..........................................................................................................1-1
1.2.2.2 Planning ...............................................................................................................1-1
1.2.2.3 Execution..............................................................................................................1-2
1.2.2.4 Testing .................................................................................................................1-2
1.3 Power and Data line protection ..........................................................................................1-3
1.4 Warranty.............................................................................................................................1-3
1.5 FCC Warning......................................................................................................................1-3
1.6 Overview.............................................................................................................................1-4
2 Installation Information ........................................................................................................ 2-5
2.1.1 Procedures ..................................................................................................................2-5
2.2 Configuration Diagram........................................................................................................2-7
2.2.1 NeXGen to Gilbarco/Bennett.......................................................................................2-7
2.3 Communication Cable and RJ45 Pin Assignments ............................................................2-8
2.3.1 POS Communication ...................................................................................................2-8
2.3.1 Gilbarco Pump and CRIND Communication................................................................2-9
2.3.2 Gilbarco Security Module Communication ................................................................2-10
2.3.3 Bennett Dispenser Communication ...........................................................................2-11
2.3.4 Bennett/Verifone CAT Communication......................................................................2-11
2.3.5 OPW OPT .................................................................................................................2-12
2.3.6 Tank Gauge Communication.....................................................................................2-13
2.3.6.1 Veeder Root TLS 250/350.................................................................................. 2-13
2.3.6.2 Veeder Root TLS 450.........................................................................................2-13
2.3.6.3 Red Jacket ST....................................................................................................2-14
2.3.6.4 Omntec...............................................................................................................2-15
2.3.6.5 OPW EECO .......................................................................................................2-15
2.3.6.6 Incon Tank Sentinel ...........................................................................................2-16
2.3.6.1 TS-550EVO........................................................................................................2-16
2.3.7 Car Wash Communication.........................................................................................2-17
2.3.7.1 Ryko III and Kesseltronics Standard..................................................................2-17
2.3.7.2 Ryko IV (S/N less than 166600), Unitec POS 4000, Portal Ti, Exacta & DRB... 2-17
2.3.7.3 Unitec Enterlink, Smart terminal and Ryko IV (S/N 166600 or greater) ............. 2-18
2.3.7.4 PDQ....................................................................................................................2-18
2.3.7.5 Kesseltronics Advanced dual bay via the MUX PAP isolator box......................2-19
2.3.8 Fuel Price Sign Communication ................................................................................2-20
2.3.8.1 Daktronics Fuel Price Sign (Minimum version required is 5.8) ..........................2-20