AT-GS900MX Series Installation Guide for VCStack
81
3. Enter the STACK ENABLE command to activate VCStack on the
switch, as shown in Figure 33:
Figure 33. Activating VCStack with the STACK ENABLE Command
4. Enter the EXIT command to return to the Privileged Exec mode, as
shown in Figure 34.
Figure 34. Returning to the Privileged Exec Mode with the EXIT Command
5. Enter the WRITE command to save your change, as shown in
Figure 35.
Figure 35. Saving the Change with the WRITE Command
Note
If this is the initial management session of the switch, the WRITE
command automatically creates, in flash memory, a new
configuration file called DEFAULT.CFG in which it stores your
configuration change. You may change the name of the file or
designate a different file after you create the stack.
6. Restart the switch with the REBOOT command, as shown in
Figure 36.
Figure 36. Rebooting the Switch with the REBOOT Command
7. Type “Y” for yes.
8. Wait one minute for the switch to initialize its management software.
awplus(config)# stack enable
% The device needs to be restarted for this change to take effect.
awplus(config)#
awplus(config)# exit
awplus#
awplus# write
Building configuration ...
[OK]
awplus#
awplus# reboot
reboot system? (y/n):
awplus#