EasyManua.ls Logo

Allison B 300 - Code 41 XX - Open or Short-To-Ground in Solenoid Circuit

Allison B 300
396 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Copyright © 1998 General Motors Corp. 661
WTEC II ELECTRONIC CONTROLS TROUBLESHOOTING MANUAL
Figure 6–21. Code 41 Schematic Drawing (Units Produced Prior To 9/94)
D 3
107 GREEN
A 7
F SOL HI
D 3
A
B
C
41 14
E
41 16
B
41 13
D
41 15
A
41 12
K
41 25
G
41 22
A
B
A
B
A
B
A
B
A 3
A 30
A 4
A 1
120 WHITE
TRANSMISSION
A 20
A 2
102 ORANGE
A 2
H 1
111 GREEN
A 11
B 1
128 ORANGE
A 28
B 2
121 VIOLET
A 21
E 1
129 VIOLET
A 29
C 1
103 GREEN
C 2
130 YELLOW
F 1
104 WHITE
D 2
110 WHITE
A 10
A
134 YELLOW
A 34
B
109 BLUE
A 9
A SOL
SOLENOID
GROUND 1
D SOL
J SOL
B SOL
SOLENOID
GROUND 2
E SOL
C SOL
SOLENOID
GROUND 3
G SOL
F SOL LO
K SOL HI
K SOL LO
A 1
A 2
D 1
B 1
B 2
E 1
C 1
C 2
F 1
D 2
A
B
D 1
131 BLUE
A 31
A
B
A
B
F
41 21
H 3
116 YELLOW
A 16
N SOL HI
H 3
H 2
101 BLUE
A 1
N SOL LO
H 2
A
B
*N
41 26
RTDR
ECU
A
B
H
41 23
A
127 WHITE
A 27
B
122 VIOLET
A 22
H SOL HI
SOLENOID
GROUND 4
ACCUMULATOR OR T-CASE
*J
41 24
H 1
B
A
V01605
ECU
A
A 9
A 1
A 18
A 27
A
(BLACK/WHITE)
NOTE: These wires may pass through a bulkhead connector.
*Only present on MD 3070 models.
SEE NOTE
SEE NOTE
SEE NOTE
SEE NOTE
SEE NOTE
SEE NOTE
CODE 41 XX — OPEN OR SHORT-TO-GROUND IN SOLENOID CIRCUIT

Table of Contents

Related product manuals