3 Operation and care
The room control unit reflects the programme areas
(heating, domestic hot water, …) from the heating and
heat pump controller.
The room control unit can be used to read out, change
and optimise the most important parameters and oper-
ating data of these programme areas conveniently in
the home.
The room control unit can be used to control the pro-
gramme areas “Heating” and “Cooling” with room tem-
perature influence.
“9 Operation”, page 10
NOTE
The prerequisites for the functionality of the
room control unit are:
● Control unit of the heating and heat pump
controller with RS485 interface.
If the existing control unit has software ver-
sion V1 and no RS485 interface, an ex-
change (update package) is necessary at a
charge. In this case:
► After replacing the control unit, install
software version F1 ≥ 1.86.
● Software version of the heating and heat
pump controller:
● for V1: Update to F1 ≥ 1.86
● for V2: ≥ 2.86
● for V3: ≥ 3.86
● with V4, the room control unit cannot
be used
Hardware requirements for some programme
areas
The programme areas “Swimming pool heating”, “Pho-
tovoltaics” and “Solar heating” described in this oper-
ating manual require, in addition to the conditions of
the system, certain hardware equipment (accesso-
ries subject to a charge) for the heating and heat pump
controller:
● for software versions F1 and V2:
comfort board
● for software version V3:
expansion board
The “Ventilation” programme area is only available in
the combination of an air/water heat pump with soft-
ware version F1 plus ventilation circuit board and Ven-
Tower.
In addition, these programme areas must be enabled
on the heating and heat pump controller.
Operating manuals of the heating and heat pump con-
troller and the respective additional board
3.1 Energy-conscious and
environmentally-aware operation
The generally accepted requirements for an ener-
gy-conscious and environmentally-aware operation of
a heating system also apply when using a heat pump.
The most important measures include:
● No unnecessarily high flow temperature
● No unnecessarily high domestic hot water tem-
perature (note and follow local regulations)
● Do not open windows with gap / tilt open (continu-
ous ventilation), but instead open wide for a short
time (shock ventilation).
● Make sure that the controller settings are correct
3.2 Care
Wipe down the outside of the unit only using a damp
cloth or cloth with mild cleaning agent (washing-up liq-
uid, neutral cleaning agent). Do not use any harsh,
abrasive, acid or chlorine-based cleaning agents.
4 Scope of delivery
1 Room control unit with touch display
2 Wago Press Tool
3 Wall holder
4 Operating manual (not shown above)
► Check delivery immediately after receipt for exter-
nally visible damage and completeness.
► Notify supplier of any defects immediately.