EasyManua.ls Logo

Alpha-InnoTec RBE+ - Settings on the Heating and Heat Pump; Influencing Factor RT

Alpha-InnoTec RBE+
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
Subject to change without notice | 83030100dUK | ait-deutschland GmbH
7 Settings on the heating and
heat pump controller
1. Under “remote control, select the “RBE” menu
item and confirm.
2. Scroll all the way down.
3. Save the settings.
4. Return to the previous menu level.
5. Go to the menu item “RBE”, select it and make the
settings.
7.1 Influencing factor RT
The influencing factor RT (room temperature) is used
to define how much the room temperature difference
is to affect the return setpoint temperature calculated
using the heating curve.
Adjustment range 0 % to 200 % in 10 % increments.
0 % pure outdoor temperature-dependent control
100 % 1K temperature difference in the room re-
sults in 1K adjustment of the return setpoint
temperature
200 % 1K temperature difference in the room re-
sults in 2K adjustment of the return setpoint
temperature
ENERGY SAVING TIP
It is recommended to include the room tem-
perature. This allows external energy inputs
can be taken into account better and the sys-
tem temperature of the heat pump can be ad-
justed in line with the requirements.
Guide values for the influencing factor RT:
Underoor heating 100 %
Radiators / fan coils 200 %
NOTE
If the main room is heated excessively com-
pared to other rooms in the home (e.g. by a
stove), and the influencing factor RT is set at an
excessively high level, this can result in loss of
comfort in other rooms in the home. Because
the temperature input in the main room low-
ers the temperatures and therefore the heating
system output in the other rooms
.
NOTE
The influencing factor RT basically depends
on the condition and characteristics of the
heat distribution system.

Related product manuals