AlphaVision ML User manual Rev. 2.60 – 01-01-2015 19
The time switch programming screen on the keypad is as follows :
D00:00 A00:00
P00: 00 S.... N
D00:00 is the disarming time in the morning
A00:00 is the arming time in the evening
P00:00 is the pre-arming signal time, often several minutes for the switch (A00:00) .
S.... is the section(s) that is armed/disarmed .
An example of an actual time switch programming for all working days ( not include Saturday and Sunday )
is as follows :
D08:30 A18:30
P18: 25 S12.. N
The AlphaVision ML will disarm section 1 and 2 every weekday at 08:30. At 18:25 on every weekday a pre-
arming signal will be heard through the speaker, the pre-arming signal will be heard every minute (18:26 ,
18:27 , etc. . ) up until 18:30 in which the system will automatically arm section 1 and 2.
Users
The Users menu is used for creating and modifying user codes. Up to 90 user codes can be programmed, for
each code the following settings have to be made:
code
authorization level
valid days
section(s)
username
Select the Users menu and press <#/OK>. The display will change to:
USER 01
01/90 <OK>
Enter the required user number (01 to 90) or use the and navigator keys to select the desired user
code. Press <#/OK> and the display will change to:
01: 000000 lev 0
smtwtfs 1234
Press to jump to the ‘code’ field. Enter the 6-digit user code and press to move onto the
‘authorization level’ field.
►!
From software version 2.00 and above the AlphaVision ML is protected against the programming of
the same usercode twice.
►!
If the programming option 4-digit codes is selected (Installer menu / System Options / User Codes)
then the last 2 digits of the user code is ignored.