The speech plug-on board also offers the opportunity to remotely arm and disarm the system or activate/
deactivate an output. Make sure any of the other options are executed before pressing <9>!
►! Remotely arming (key 4 and 6) - and disarming (key 0) has a danger. Each private phone number
being called can perform this option regardless of the actual authorization of the called party !
When the ‘Activate Output’ function is executed, key <7> will activate the programmed output and key <8>
will deactivate the output. The control panel can also activate the output for a short time (1 second, single
pulse). If this is programmed, both key <7> as <8> will activate the output for 1 second. Consult the
installation company for more information.
When the AlphaVision ML control panel is equipped with both a speech plug-on board as well as a keypad
with integrated speaker and microphone, a speakerphone or separate speaker and microphone, the called
party can activate a semi-duplex speech/listen-in session. Use the following keys on the telephone for this
function:
Key 1: Listen-in
Key 2: Speak
Inactivity
The AlphaVision ML can be programmed to contain an ‘inactivity’ function with certain zones. The inactivity
function sends out an alarm to a monitoring station or private telephone number when NO activity (the
detector did not sense any motion) was registered for the programmed zones during a certain period of
time. This function can be very handy for elderly or physically challenged people. The inactivity functions is
only active when the section(s) that the specific inactivity zones are linked to, are disarmed.
Remote control of the AlphaVision ML
When the speech plug-on board is used, the AlphaVision ML control panel can be remotely controlled by
using a (mobile) telephone (this option has to be enabled in the programming). All functions as described in
the ‘Reporting to private telephone’ chapter can be executed from a telephone. This option can be useful
when the user forgot to arm the system or wishes to remotely disarm it.
When the AlphaVision ML control panel is equipped with both a speech plug-on board as well as a keypad
with integrated speaker and microphone, a speakerphone or separate speaker and microphone, the called
party can also activate a semi-duplex speech/listen-in session.
For remote control or remote service the installation company will program the AlphaVision ML control
panel to accept incoming calls. There are two options: single ring-in or double ring-in.
Single ring-in
Dial the telephone number of the AlphaVision ML control panel and allow the line to ring 4 times. The
AlphaVision ML will automatically pick up the line and prompt for a valid 6-digit user code. Enter a valid user
code. When accepted, the AlphaVision ML will play the house ID (if recorded) to confirm you are connected
and are in the main menu. For further options, see chapter ‘Reporting to private telephone’.
Double ring-in
Dial the telephone number of the AlphaVision ML control panel and allow the line to ring 4 times. Hang up
the line and wait for at least 20 seconds. Redial the AlphaVision ML, the control panel will automatically pick
up the line after 4 rings and establish the connection. The procedure is similar to Single call.