TROUBLESHOOTING
Self -Cle ani n g Ro tis se rie Ove n ▪ Ser v i ce M anual ▪ MN- 392 4 3 ▪ Rev 1 ▪ 2/ 19
56
Spit Motor Inoperable
Before you start Navigate to the Service screen. Touch the M2 icon.
WARNING: Electric shock and arc flash hazard.
Use caution when measuring line voltage.
Wear Personal Protective Equipment (PPE).
Is the LED next to RY3 on the control board
illuminated?
No
Replace the control board.
Yes
Measure AC voltage across the normally open
terminal of RY3 on the control board and TB7. Does
the voltage correspond to the voltage printed on the
serial number tag?
No
Replace the control board.
Yes
Replace the spit motor.