Troubleshooting
All troubleshooting trees based on a 7-20 208/240V 3ph model runnin at “ECO” power setting unless otherwise noted.
PROformance: Appliance Dead — No Display or Operation
Is power connected to the appliance?
No
Install power to the appliance, turn on main circuit breaker or
plug in the appliance.
Yes
Is there correct voltage at the power source(outlet)?
No
Inspect and/or reset the circuit breaker.
Yes
Is there correct voltage at the main terminalblock(L1/2/3)?
No
Repair or replace the faulty cord, plug, or wiring.
Yes
Is there voltage at the F1 fuse block?
No
Repair the wiring.
Yes
Is there continuity through the terminalmodule 8A fuse?
No
Replace the fuse and test.
Yes
Is there voltage across L/N at the power supply?
No
Inspect/Repair wiring between terminalblock33-3 and power
supply terminalL, and between terminalblockterminal27-1
and power supply terminalN.
Yes
Is there 12 VDC output from the power supply?
No
Replace faulty power supply.
Yes
Is there 12 VDC across the Control Board(CB) terminalX07
pins1-4?
No
Repair wiring between power supply and the Control
Board(CB) terminalX07.
Yes
Is there 12 VDC across Interface Board(IB) terminalX07
pins1-4?
No
Repair the wiring between Control Board(CB) X07 and
Interface Board(IB) X07.
Yes
Inspect, test and repair or replace the following connections
and components as needed.
Is the ethernet connection between the Interface Board(IB)
X06 and the Control Board(CB) X15 okay?
No
Repair the ethernet connection.
Yes
Is the Interface Board(IB) or touch display backlight
cableconnection X04 okay?
No
Repair the cableconnection X04.
Yes
Is the Interface Board(IB) or touch display connector
cableX03 okay?
No
Repair cableconnection X03.
Yes
Is the Interface Board(IB) or touch display or LVDS cableX01
okay?
No
Repair the LVDS cableX01.
Yes
Is the Interface Board(IB)on/o board input at X05 okay?
No
Repair on/o input X05.

Table of Contents

Other manuals for Alto-Shaam Combitherm CT PROFORMANCE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alto-Shaam Combitherm CT PROFORMANCE Series and is the answer not in the manual?

Alto-Shaam Combitherm CT PROFORMANCE Series Specifications

General IconGeneral
BrandAlto-Shaam
ModelCombitherm CT PROFORMANCE Series
CategoryOven
LanguageEnglish

Related product manuals