67
Troubleshooting
PROformance: No Grease Collection Operation
Is the appliance equipped with a grease collection(GC)
pump?
No
Grease collection system is not available.
Yes
Is the control set up to operate a GC system?
No
Turn on grease collection in option set up screen.
Yes
Is grease collection activated in the cooking program?
No
Activate grease collection in the program and retest.
Yes
Is the grease collection pump being energized on its timed
cycle?
No
Determine which leg of the power is missing and correct.
A1 is L1 being switched from Control Board(CB)
terminalX02 which is supplied by Option Board(OB)
terminalX02 pin1.
A2 is L2 supplied by CB terminalX02 pin3 which is
supplied from OB terminalX02 pin4.
Yes
Is the grease collection pump running?
No
Replace the faulty grease collection pump.
Yes
Remove pump and clear obstruction between condensate pan
and pump, or between pump and grease collection bin.