Combitherm® CT PROformance™ and CT Classic™ Series Technical Service Manual
71
Troubleshooting
PROformance and Classic: No Rinse Water During the Cleaning Cycle
Is the Wash Cycle Rinse Water Y3 solenoid being energized
on its timed cycle?
No
Determine which leg of the power is missing at the Y3
solenoid and correct.
A1 is L1 supplied from the Control Board(CB) terminalX04
pin2.
A2 is L2 supplied from terminalblock27-17.
Yes
Is the Y3 solenoid opening?
No
Replace the faulty solenoid.
Yes
Is there water at the rinse water flow control valve?
No
Repair the hose between the Y3 solenoid and rinse flow
control valve.
Yes
Is the rinse flow control valve clean of debris?
No
Clean or replace the rinse flow control valve.
Yes
Is water at the injection pipe of the appliance?
No
Clean or repair water manifold and/or hose from manifold to
the injection pipe.
Yes
Is the injection pipe clear of debris?
No
Repair or replace the injection pipe as needed.
Yes
The rinse water plumbing should be working properly.

Table of Contents

Other manuals for Alto-Shaam Combitherm CT PROFORMANCE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alto-Shaam Combitherm CT PROFORMANCE Series and is the answer not in the manual?

Alto-Shaam Combitherm CT PROFORMANCE Series Specifications

General IconGeneral
BrandAlto-Shaam
ModelCombitherm CT PROFORMANCE Series
CategoryOven
LanguageEnglish

Related product manuals