SERVICING
53
SUCTION LINE
BULB
1/4 FLARE CONNECTION
EXPANSION VALVE
EVAPORATOR COIL
REMOVE BEFORE INSTALLING EXPANSION VALVE
SEAL SUPPLIED W/ KIT
SEAL SUPPLIED W/ KIT
BULB TO BE LOCATED
AT 10 OR 2 O'CLOCK
For Applications requiring
a field installed access fitting
TAILPIECE
3/8"-
SWEAT
7/8" NUT
DISTRIBUTOR
BODY
PISTON
SEAL
EVAPORATOR COIL
1/4' FLARE
CONNECTION
BULB
SUCTION LINE
EXPANSION VALVE
REMOVE BEFORE
INSTALLING
EXPANSION VALVE
SEAL SUPPLIED W/ KIT
SEAL SUPPLIED W/ KIT
BULB TO BE LOCATED
AT 10 OR 2 O'CLOCK
TAILPIECE
3/8"-
SWEAT
7/8" NUT
DISTRIBUTOR
BODY
PISTON
SEAL
For Applications
not requiring
a field installed access fitting
