For keyfob it is possible program some different parameters:
- Silent panic combination buttons ( info button silent, press and hold for 2 seconds)
- panic combinations ( * button panic, press and hold for 2 seconds)
- link user
- partials per button, link 1 or more partitions to the every buttons
- outs per button, link out to the button
- and it is possible enable the led on key fob for the operation, all programmable
- * button for panic with siren
For the button with * simbol it is possible enable the siren panic,
(1 = enable 0 = disable) if the * is pressed fo 2 seconds the
system will go in siren panic
- INFO button for SILENT panic
For the button with * simbol it is possible enable the siren panic,
(1 = enable 0 = disable) if the * is pressed fo 2 seconds the
system will go in siren panic
- link the keyfob to the user
in figure the keyfob is linked to user n°1
- Link butoon of keyfob to the partitions
it is possible link one or more buttons of keyfob to the 1 or more
partitions and it is possible change the function of button: ON,
OFF, and ON/OFF (ON/OFF = 1 pression ON -> another pression
OFF) In this LCD mask PRESS ENTER TO MODIFY. It is possible
modify these parameters for all buttons.
In figure is shown that the Key TOT button is programmed like
only ON and are linked the partitions: 1345678