SYSTEM RESET MENU
The parameter reset on the control unit can only be done with the installer code.
Resets are done in a specific menu and are divided into 3 categories:
- users codes menu reset
- configuration reset
- events memory reset (can only be done by the manufacturer)
IMPORTANT: if the installer code is lost, the control unit must return of producer.
Fig 1 With this time of reset, all of the user codes and related parameters are deleted,
except for the first one that is set to the default value (111111)
Fig. 2 With this type of reset all of the control unit parameters are set to default except
for the event log which cannot be deleted.
Fig. 3 With this parameter you can reset the entire event log. Only the manufacturer
can perform this operation for security reasons.
fig 3
fig 2
fig 1
SYSTEM RESET
Configuration
SYSTEM RESET
Events Memory
EDIT VOCABLES MENU
With thi s menu it is possible to change some word of vocabolary for the name of zone, ouput, ext.
In the K series, where is not audio support it is possible change all words:
- select vocables list from EDIT VOCABLES menu
- select the number or the vocables that is be changed (for K all, for X first 30 words)
- press ENTER and use the alphanumeric keypad for modify
In X series where there is pre record vocabulary, there is the possiblity to add 30 recordable words to the vocabulary:
- select vocables list from EDIT VOCABLES menu
- select the number or the vocables that is be changed
- press ENTER and use the alphanumeric keypad for modify
- select audio messages
- the number of place from 1 to 30
- press * to play and select X to record new audio.
MENU PRIORITY VECTOR
With this menu it is possible select the sequence of vector priority for sending message to the monitoring station and to the user.
The vector are:
- PSTN
- GSM
- LAN
- GPRS
For set the sequence, set the vector in numbering order, from 1 to 4, with verti-
cal arrow select the number of order, with buttons 1 - 2 - 3 - 4 select the vector.