74
03/2010 Rev. 0.1
03/2010 Rev. 0.1
75
Service menu continued ….
Main item Sub item Sub Item Range Description
2.3 Recipe setting
(continued…)
Recipe name 1
Recipe name 12
DV 4 WT 0,0-30,0 s Waiting time Water 4
DV 4 0,0-100,0 ml
Dispensing amount Water 4
(Hot water dispensed)
DV 5 WT 0,0-30,0 s Waiting time Water 5
DV 5 0,0-100,0 ml
Dispensing amount from an extra hot water
valve Water 5 (reserved for a Brewer
By-Pass option).
DV 6 WT 0,0-30,0 s Waiting time Water 6
DV 6 0,0-100,0 ml
Dispensing amount from an extra inlet
valve Water 6 (Cold Water option)
Strength Coffee 0-50% Use the strength setting item to add an
ingredient to the strength adjustment.
Ingredient strength adjustment:
0= off / > 1 = on
Example: [coffee] 20%
Example: [cocoa] 40%
None 0-50%
Strength Chocolate 0-50%
Strength Topping 0-50%
Strength Sugar 0-50%
Strength Ingrediënt 6
Option
0-50%
Strength
-- - 0 + ++
-20% -10% 0 10% 20%
Strength
-- - 0 + ++
-40% -20% 0 20% 40%
Service menu continued…
Main item Sub item Item Range
Set-
ting
Description
2.4 Settings Language English Language choice display.
Ex factory setting English.
Dutch
German
French
Temperature
Temp. boiler 70-97°C *
95°C *
Boiler temperature standard model
1K - 5K + AK
90°C *
Boiler temperature FreshBrew +
instant model 6A t/m 9A
Hysteresis 2-10°C 2°C
Temperature drop, after which boiler
must reheat
Output block 70-90°C 78°C
Boiler temperature disables dispens-
ing. Display: [Out of order, boiler
heating]
Output release 70-90°C 85°C
Boiler temperature allows dispens-
ing again
Stand-by 60-80°C 60°C Boiler temperature during stand-by
Extended Heating 0-5 sec 1 sec
To maintain the optimum boiler tem-
perature the heating element and
inlet valve switch on simultaneously.
Set the waste delay of the element
here after the inlet valve is closed.
Inlet valve
Heating
Display Show clock Yes/no No Show clock in display
Show date Yes/no No Show date in display
Message text Yes/no No
Show message text (running text) in
display. Only shown if Display Date,
Clock or both are set to no.
Message text only programmable
by using the Optimizer programme
and SD card.
Use bleeper Yes/no Yes Sound signal on or off
Fan time 0-300 sec. 60 s.
Duration of Fan speed 2 after
dispensing
Fan speed 1 40-100% 50% Fan speed when resting
Fan speed 2 40-100% 100% Fan speed during dispensing
Inlet valve
Heating