Page 28 of 39 Technical Documentation ECE10CM, DC10CM
n-max Maximum speed setting
1. Rough adjustment via S1-1, S1-2 &. R161
(See Chapter 5.4)
2. Specify maximum set point voltage (10V).
3. Set max. required speed on "n-max“ trimmer
(See sketch for trimmer OFFSET).
4. Check at "n-ACT“ test jack.
I-max Equipment peak current setting
External current default "I-LIMIT (X5-7)“ at analogue input
Apply potential ≥ 10 V. Set required peak current at I-max. trimmer
Check at "I-max“ test jack.