APsystems YC500-A Installation/User Manual 6
A PV system using APsystems microinverters is simple to install.
Each microinverter easily mounts on the PV racking, directly beneath
the PV module(s). Low voltage DC wires connect from the PV module
directly to the microinverter, eliminating the risk of high DC voltage.
Installation MUST comply with local regulations and technical rules.
WARNING: Perform all electrical installations in accordance with
local electrical codes.
WARNING: Be aware that only qualied professionals should install
and/or replace APsystems microinverters.
WARNING: Before installing or using an APsystems microinverter,
please read all instructions and warnings in the technical documents
and on the APsystems microinverter system itself as well as on the PV
array.
WARNING: Be aware that installation of this equipment includes
the risk of electric shock.
WARNING: Do not touch any live parts in the system, including the
PV array, when the system has been connected to the electrical grid.
Additional installation components from APsystems
AC branch end cable (1 per branch, sold separately - P/N: AC
Cable - F)
Protective end cap (1 per branch, sold separately - P/N: End
Cap - F)
AC Extension Connector Cable (if required - P/N: AC - EXT)
- Available in 1m, 2m, and 4m lengths.
Required parts and tools from installer
In addition to your PV array and its associated hardware, the
following tools are required for assembly:
One AC connection junction box per branch circuit
Mounting hardware suitable for module racking
Sockets and wrenches for mounting hardware
Continuous grounding conductor and grounding washers
Phillips screwdriver
Torque wrench