8alue ‘1’ for these parameters means that the output logic is
reset to the N.O. value (default).
If the parameter is not activated in the selected scheme,
the message ‘ NONE ‘ will appear on the display.
Output logic for OUT 2
Data Regulation range Default
OUT 2 .. 1 1
Output logic for OUT 3
Data Regulation range Default
OUT 3 .. 1 1
Output logic for OUT 4
Data Regulation range Default
OUT 4 .. 1 1
Note: ‘0’ means Normally Closed (N.C.) logic, while ‘1’
means Normally Open (N.O.) logic.
The user is allowed to select the relay logic for max. 3 outputs
only listed in the following.
AFTER SELECTIN) PARAMETER P5 PRESS
T*E ‘ ‘ KEY.
j
j
SELECT T*E DESIRED OUTPUT AND
PRESS T*E ‘ ‘ KEY.
C*AN)E T*E OUTPUT LO)IC USIN)
T*E ‘ S ‘ or ‘ T ‘ ARRO9S.
j
USIN) T*E ‘ S ‘ or ‘ T ‘ ARRO9S IT IS POSSI$LE TO
SCROLL T*ROU)* T*E ACTI8E OUTPUTS.
j
PRESS T*E ‘ ‘ KEY TO CONFIRM T*E PRO)RAMMED
SETTIN) OR PRESS T*E ‘ esc ’ KEY TO CANCEL T*E
MODIFICATION.