Initial start-up
33 / EN
Inverter error
Description Code (for inverter errors falling
within error code 931)
NIMBUS EXT R32
35 S - 50 S -
80 S
80 S-T
Inverter output current sensor error 1 x x
DC bus condensers pre-charge error 2 x
Inverter input voltage sensor error 3 x
Inverter heat sink temperature sensor error 4 x x
DSP&MCU communication error 5 x
Inverter input AC overcurrent 6 x x
Inverter PFC current sensor error 7 x
Inverter PFC temperature sensor error 8 x
Corrupt EEPRPOM 9 x
PFC HW overcurrent 10 x
PFC SW overcurrent 11 x
Inverter PFC overvoltage 12 x
A/D error 13 x
Addressing error 14 x
Compressor inverse rotation 15 x
No current variation on compressor phase 16 x
Misalignment between real and calculated speed 17 x x