EasyManuals Logo

Ariston NIMBUS M NET User Manual

Ariston NIMBUS M NET
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
Initial start-up
32 / EN
Outdoor unit errors
Error Description NO RESET RESET
Volatile User reset HP Power
OFF
Service reset
1 TD sensor error - X - -
905 HP compressor mismatch error - - X -
906 HP fan mismatch error - - X -
907 HP 4-way valve mismatch error - - X -
908 Expansion valve mismatch error - - X -
909 HP zero fan speed - - X -
910 Inverter-TDM communication error X - - -
912 4-way valve error - - - X
913 LWT sensor error X - - -
914 TR sensor error X - - -
917 Freeze error - - - X
918 Pump down error - - - X
922 Freeze error - X - -
931 Inverter error X - - -
947 4-way valve error - X - -
956 HP compressor model mismatch - - X -
957 HP fan model mismatch - - X -
960 HP EWT sensor error X - - -
962 Defrost error X - - -
968 ATGBUS TDM-EM communication error X - - -
989 Machine empty error - - - X
997 Compressor overcurrent - - X -
998 Compressor overcurrent - - - X
9E5 High-pressure pressure switch intervention X - - -
9E8 Low-pressure pressure switch error with
compressor OFF
X - - -
9E9 Klixon error with compressor OFF X - - -
9E18 ST1 safety thermostat error X - - -
9E21 Low refrigerant charge error - X - -
9E22 Machine empty error - - - X
9E24 EXV seized up error - X - -
9E25 EXV seized up error - - - X
9E28 High-pressure protection - X - -
9E29 High-pressure protection - - - X
9E31 Compressor thermostat protection - X - -
9E32 Compressor thermostat protection - - - X
9E34 Low-pressure protection - X - -
9E35 Low-pressure protection - - - X
9E36 Compressor phases current imbalance - X - -
9E37 Compressor phases current imbalance - - - X
9E38 Excessively steep compressor current variation - X - -
9E39 Excessively steep compressor current variation - - - X

Table of Contents

Other manuals for Ariston NIMBUS M NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston NIMBUS M NET and is the answer not in the manual?

Ariston NIMBUS M NET Specifications

General IconGeneral
TypeAir-to-Water Heat Pump
RefrigerantR32
Power SupplyElectric
Power Supply Voltage230 V
ConnectivityWi-Fi
Heating Capacity6 kW