Electromagnetic Compatibility
Sara Flex has been tested for compliance with current regulatory standards regarding its capacity to block
EMI (electromagnetic interference) from external sources. Nonetheless, some procedures can help reduce
electromagnetic interferences:
Ensure that other devices in patient-monitoring and/or life-support areas comply to accepted
emissions standards.
Maximize the distance between electro-medical devices. High-powered devices may produce EMI
that can affect the lift.
For more information on how to manage the unit’s RF electromagnetic environment, please consult
the AMI TIR 18-1997 - Guidance on Electromagnetic Compatibility of Medical Devices for Clinical/
Biomedical Engineers.
Sara Flex LVLQWHQGHGIRUWKHXVHLQWKHHOHFWURPDJQHWLFHQYLURQPHQWVSHFL¿HGEHORZ7KHFXVWRPHURUWKH
user of Sara Flex should assure that it is used in such an environment.
WARNING
Portable RF communications equipment (including peripherals such as antenna
cables and external antennas) should be used no closer than 30 cm to any part of the
6DUD)OH[LQFOXGLQJFDEOHVVSHFL¿HGE\WKHPDQXIDFWXUHU2WKHUZLVHSHUIRUPDQFH
degradation of this equipment could result.
WARNING
8VHRIDFFHVVRULHVFDEOHVDQGVSDUHSDUWVRWKHUWKDQWKRVHVSHFL¿HGRUSURYLGHGE\
Arjo could result in increased electromagnetic emissions or decreased electromagnetic
immunity of this equipment and result in improper operation.
WARNING
Use of this equipment adjacent to or stacked with other equipment should be avoided
because it could result in improper operation. If such use is necessary, this equipment
and the other equipment should be observed to verify that they are operating normally.
WARNING
The equipment may cause radio interference or may disrupt the operation of nearby
equipment. It may be necessary to take action, such as reorienting, relocating the
equipment or shielding the location.
Guidance and manufacturers declaration: electromagnetic emissions
Emissions test Compliance Electromagnetic environment - guidance
RF emissions
CISPR 11
Group 1 Sara Flex uses RF energy only for its internal function. Therefore,
its RF emissions are very low and are not likely to cause any
interference in nearby electronic equipment.
RF emissions
CISPR 11
Class B Sara Flex is suitable for use in all establishments, including
domestic establishments and those directly connected to the public
low voltage power supply network that supplies buildings used for
domestic purposes.