13.2.2. Control input-output signals:
13.2.2.1. Relay outputs:
Relay output specifications:
Error output.
In normal situation the relay remains activated. In the
event of a failure, the relay will be released. In order to
cut off the error signal in case of a failure use the NO
contact outputs (RHO-RHA).
Driver running relay NO
contact
Driver running signal output.
This output should be used when the lift controller
releases the main contactors with a release command
coming from the inverter. The relay remains activated
during the drive.
Driver running relay COM
contact
Mechanical brake relay
NO contact
Mechanical brake contactor output.
The drive activates the relay in order to release the
mechanical brake.
Mechanical brake relay
COM contact
Note: It is recommended to protect inductive loads with noise-reducing circuits (i.e. varistors or
AC filters for AC voltages, diodes for DC voltages).