ARKEL 117 ADrive
ENGLISH
TÜRKÇE
13.2.7. Manual evacuation mode activation input
ADrive can be informed that the manual evacuation mode is active, through a high level at the
PI3 input on ENCABIT-Plus module.
When the input PI3 is activated, a special evacuation screen appears on ADrive display.
A similar screen is also appears on ADrive Remote Keypad display. The following information
is shown in the manual evacuation mode screen:
The direction of car
The speed of car
Over speed warning (The evacuation speed must not exceed 0.63 m/s)
SPEED : 0.4 m/s
DIR : ↑
When the manual evacuation mode is activated, the speed (m / s) is
shown on the top line and the direction (↑ or ↓) is shown on the
bottom line of the evacuation screen.
SPEED : 0.65 m/s
STOP!!! (V>0.63)
When the evacuation speed exceeds 0.63 m/s, a warning message
will be shown on the bottom line of the evacuation screen. In such a
case, the operation must be stopped.
According to EN 81-1/A2 6.6.2.c, during emergency evacuation, the following
information must be given in cases that the drive machine cannot be observed directly:
- The direction of car
- The speed of car
- Door unlocking zone
We recommend using one of ARKEL products LEVELED board for indicating the door
unlocking zone information.
S-EV: NO contact of manual evacuation mode
activation switch
ENCABIT