EasyManua.ls Logo

Arkel ADrive VVVF - Page 135

Arkel ADrive VVVF
166 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ARKEL 133 ADrive
ENGLISH
TÜRKÇE
TOTAL TRAVEL:
0000358 RUN/STOP
TOTAL NUMBER OF TRAVEL SCREEN
The total number of travel of elevator in run/stop is displayed on this
screen.
CAN_BUS: 1920 p/s
RS485 : 800 p/s
SERIAL COMMUNICATION MONITORING SCREEN
CAN_BUS: The number of packets per second of CANbus serial
communication between ENCABIT-Plus module and ADrive.
RS485: The number of packets per second of RS-485 serial
communication (with ADrive Remote Keypad or lift controllers)
Vref : 1.20 m/s
Vact: 1.19 m/s
SPEED MONITORING SCREEN
Vref: Reference (target) speed
Vact: Actual (current) speed
Encabit PI:01000
Enc_pos : 001A3f22
ENCABIT-Plus MONITORING SCREEN
Encabit PI: The state of the 5 digital inputs (PI1-PI5) on ENCABIT-
Plus module (1: input active / 0: input inactive).
PI1
PI2
PI3
PI4
PI5
Encabit PI:
0
1
0
0
0
Enc_pos: The hexadecimal value of 21-bit absolute encoder position.
ADrive SW: V8.30
Encabit SW: V1.03
SOFTWARE VERSION SCREEN
The software version of ADrive inverter and ENCABIT-Plus module.
B.Resistor : % 4
**▪▪▪▪▪▪▪▪▪▪▪▪▪
BRAKING RESISTOR USING SCREEN
The using rate of braking resistor during braking.

Table of Contents