5-14 CHP Max™ Headend Optics Platform Chassis, Controllers and Power Supplies Rev D
5. Double-click the CMM-1 or SMM-1 module identifier in the module inventory on the
left side or double-click on the CMM-1 or SMM-1 module in the chassis image map
to open the management window.
6. Verify that the firmware version running on the SMM-1 or CMM-1 is 4.034 or later. If
necessary, refer to Updating the CHP-CMM Microcontroller Firmware on page 5-28 to
download the updated firmware into the SMM-1 or CMM-1.
7. If the On radio button in the Autoconfig window is selected, click the Off radio
button in the Autoconfig window to disable the auto-configuration mode.
8. Shut down the CHP GUI and then restart the CHP GUI.
9. In the CHP GUI, select Tools > Firmware Download to update or change a selected
module’s firmware.
Figure 5.11
Firmware Download
Method 1
10. Double-click the module that is to receive the firmware update.
Note Shutting down and restarting the CHP GUI forces the firmware download to
start loading from the beginning of the first firmware file in the module.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Arris CHP Max5000 and is the answer not in the manual?

Arris CHP Max5000 Specifications

General IconGeneral
BrandArris
ModelCHP Max5000
CategoryMulti-service Platforms
LanguageEnglish

Related product manuals