EasyManua.ls Logo

Arris CHP Max5000 - AC Power Supply Specifications

Arris CHP Max5000
267 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rev D CHP Max AC Power Supply 4-17
AC Power Supply Specifications
Table 4.6 CHP AC Power Supply Specifications
Characteristic Specification
Electrical CHP-PS/AC1-Q CHP-PS/AC1-SW
Input Voltage (47 to 63 Hz) 85 to 264 V
AC 85 to 264 VAC
Input Current Limit, max., continuous,
RMS
6.0A 9.0A
Inrush Current Limit, max., peak 30A 40A
Input Transient
(IEEE C62.41-1991 Category B 1.2,
50μs)
4kV/0.13kA 4kV/0.13kA
Power Consumption, max. 250W 475W
AC Input Inlet Connector IEC 320-C14 (mates with IEC 320-C13
power cord)
IEC 320-C14 (mates with IEC 320-C13
power cord)
Output Voltages and Current 12.0 (+0.35/–0.0)V
DC @ 10A
5.0 (+0.2/–0.05)V
DC @ 22 A
–5.0 (+0.05/–0.2)V
DC @ 1.8 A
3.5 (±0.1)V
DC @ 2.2 A
12.0 (+0.35/–0.0)V
DC @ 2.3 to 24A
5.0 (+0.2/–0.05)V
DC @ 31 A
–5.0 (+0.05/–0.2)V
DC @ 2 A
3.5 (±0.1)V
DC @ 5A
Output Noise Ripple, RMS (at 300 kHz,
10 μF capacitor in shunt with 0.1 μF)
25mV @ 12.0V output
25mV @ 5.0V output
20mV @ –5.0V output
20mV @ 3.5V output
25mV @ 12.0V output
25mV @ 5.0V output
20mV @ –5.0V output
20mV @ 3.5V output
Efficiency, min. 68% 68%
Power Factor 0.9 0.9
Status Interface CHP-PS/AC1-Q CHP-PS/AC1-SW
Functions Monitored All DC Voltages, Internal Temperature,
Fan Currents
All DC Voltages, Internal Temperature,
Fan Currents
Mechanical CHP-PS/AC1-Q CHP-PS/AC1-SW
External Dimensions (W x H x D) 3.9 x 1.57 x 14.46in (9.91 x 3.99 x 36.73
cm)
3.9 x 1.57 x 14.46in (9.91 x 3.99 x 36.73
cm)
Weight 2.75lb (1.2kg) 2.75lb (1.2kg)
Environmental CHP-PS/AC1-Q CHP-PS/AC1-SW
Operational Temperature Range 32 to 122°F (0 to 50°C) 32 to 122°F (0 to 50°C)
Storage Temperature Range –40 to 158°F (–40 to 70°C) –40 to 158°F (–40 to 70°C)
Humidity, max., noncondensing 95% 95%
Specifications subject to change without notice

Table of Contents

Related product manuals