1508685 Rev D CHP Max Monitorable Attributes A-7
Table A.7 CHP-EDFA/CHP-EDFA-CG Parameters
Attribute Parameter MIB Object MIB Type
Module
Identification
Serial Number
Date of Production
Firmware Revision
Hardware Revision
Pump Laser Type
ServiceTrackingNumber
entPhysicalSerialNum
chpSlotConfigModuleProductDat
e
entPhysicalSoftwareRev
entPhysicalHardwareRev
heOpAmpLaserType
chpSlotStatusModuleServiceNu
m
STANDARD
ENTERPRISE
STANDARD
STANDARD
STANDARD
ENTERPRISE
Monitorable
Parameters
Internal Temperature
Per Output Optical Power
Pump Laser Bias Current
Pump Laser Temperature
Input Optical Power
Output Optical Gain (Constant
Gain Per Wavelength Per
Output)
heCommonTemperature
heOpAmpOutputPower
heOpAmpLaserBiasCurrent
heOpAmpLaserTemp
heOpAmpInputPower
heOpAmpGainPerWavelength
STANDARD
STANDARD
STANDARD
STANDARD
STANDARD
STANDARD
Status Module On/Off Status
Front Panel Control Status
Reset Cause
Output Gain Control Mode
heOpAmpUnitOutputStatus
chpSlotConfigModuleFrontPanel
chpSlotStatusModuleResetCause
heOpAmpGainType
STANDARD
ENTERPRISE
ENTERPRISE
STANDARD
Threshold Major Low
Minor Low
Minor High
Major High
analogAlarmLOLO
analogAlarmLO
analogAlarmHI
analogAlarmHIHI
STANDARD
STANDARD
STANDARD
STANDARD
Alarm States Value of AlarmState can be
Major Low, Minor Low, Minor
High, or Major High.
currentAlarmState STANDARD
Alarm Enable
States
AlarmEnable can
enabled/disabled for the
following alarms: Major Low,
Minor Low, Minor High, Major
High.
alarmEnable STANDARD
Deadbands Deadbands may be set for each
monitorable parameter.
analogAlarmDeadband STANDARD
Firmware
Upgrades
Boot Version
Download Version
entPhysicalFirmwareRev
entPhysicalFirmwareRev
STANDARD
STANDARD