INSTALLATION GUIDE
Room Controller 4 (NIRC4-xMN) Preparing the Room Bus Cables
8 Preparing the Room Bus Cables
Prepare the room bus cables and guide the wires through the housing. Avoid pressing the wires against the
printed circuit board, as this could cause damage to the board and may also prevent the top section from
closing properly.
Stripping the Outer Jacket of the Cables
Strip the outer jacket of the cables to a length of 150mm or 6 inch, then position the cable in the backbox so
that only the stripped wires enter the room controller housing.
Figure 5. Stripping and positioning the cables for the NIRC4-xMN
TD 93351EN / 21 March 2022 / Ver. B