Overview Installation Use Maintenance Warranty
5. Technical characteristics
Model 200L 200L C 270L 270L C
Dimensions (Height x Width x Depth) mm 1617 x 620 x 665 1957 x 620 x 665
Weight empty kg 80 97 92 111
Tank capacity L 200 197 270 263
Hot water/cold water connection - ¾ ʺ M
Anti-corrosion protection - ACI Hybrid
Rated water pressure MPa (bar) 0.8 (8)
Electrical connection (voltage/frequency) - 230V~ single phase 50 Hz
Total maximum power absorbed by the appliance W 2500
Maximum power absorbed by the heat pump W 700
Power absorbed by the electrical backup W 1800
Setting range of the water temperature set point °C 50 to 62
Operating temperature range of the heat pump °C -5 to +43
Duct diameter mm 160
Air flow (without duct) in speed 1 m
3
/h 310
Air flow (without duct) in speed 2 m
3
/h 390
Permissible load losses on the air flow
Pa 25
Sound power* dB(A) 53
Refrigerant R513A kg 0.80 0.86
Refrigerant volume in equivalent tonnes T.eq.CO2 0.50 0.54
Refrigerant mass kg/L 0.0040 0.0032
Certified performance at 7°C air (CDC LCIE 103-15/C) & ducting at 30 Pa**
Coefficient of performance (COP) - 2,79 2,79 3,16 3,03
Extraction profile - L L XL XL
Absorbed power in steady state (P
es
) W 32 32 28 33
Heating time (t
h
) h.min 07:52 07:53 10:39 11:04
Reference temperature (T
ref
) °C 52,7 52,7 53,0 53,1
Air flow rate m
3
/h 320 320 320 320
* Tested in a semi-anechoic chamber in accordance with the NF 9614-2standard.
** Performance measured for a water heater from 10°C to T
ref
according to the protocol of the NF Electricity Performance Mark specifications No.LCIE 103-15C, self-
heating thermodynamic water heaters (based on standard EN 16147).
These appliances comply with the 2014/30/EU Electromagnetic Compatibility Directive, the 2014/35/EU Low Voltage Directive, the 2011/65/EU RoHS 2 Directive
and the 2013/814/EU Regulation supplementing Directive 2009/125/EC for Ecodesign.