"Accelerated decrease": ON / Stop.
"ECO / Comfort switchover" Anticipates time needed to reach the comfort setpoint.
"Comfort / ECO switchover" Anticipates time needed to switch from comfort setpoint
to ECO setpoint.
Area 1
Comfort optimisation
Accelerated decrease
Max anticipation
ECO / Comfort switchover
Comfort / ECO switchover
Stop
03:00 h
00:30 h
Comfort optimisation
Control / Temperature control
ECO mode limitation
Setting setpoint T°
"Activation outd. T°": -30°C / +10°C.
"Stoping outd. T°": -30°C / +10°C.
Area 1
ECO mode limitation
Activation outd. T°
Stoping outd. T°
---
-5°C
"Comfort T°": ECO Temperature … 35°C.
"ECO T°": Absence Temperature ... Comfort Temperature.
"Absence T°": 4°C… ECO Temperature.
" Heating temperatures factory settings:
Comfort 20°C, ECO 19°C, Absence 8°C.
" Cooling temperatures factory settings:
Comfort 24°C, ECO 26°C, Absence 35°C.
Zone 1
Comfort T° 20°C
ECO T° 19°C
Absence T° 8°C
Heating Setpoint T°