1.4 General characteristics
Model name Alféa Extensa A.I. 5 6 8 10 13 16
Rated heating performances (outdoor temp. / ow temp.)
Heat output
+7°C/+35°C - Underoor heating system kW 4.50 6.00 7.50 10.00 14.01 16.06
-7°C/+35°C - Underoor heating system kW 4.10 4.60 5.70 7.40 9.45 12.93
+7°C/+45°C - LT radiator kW 4.50 5.10 6.20 8.27 10.43 13.60
-7°C/+45°C - LT radiator kW 4.10 4.45 5.05 7.40 9.25 11.20
+7°C/+55°C - Radiator kW 4.50 4.50 5.00 7.00 7.84 10.03
-7°C/+55°C - Radiator kW 3.70 3.85 5.20 7.00 7.29 8.65
Power consumption
+7°C/+35°C - Underoor heating system kW 1.00 1.41 1.84 2.49 3.50 4.37
-7°C/+35°C - Underoor heating system kW 1.47 1.74 2.23 2.97 3.92 5.32
+7°C/+45°C - LT radiator kW 1.31 1.50 1.87 2.53 3.19 4.38
-7°C/+45°C - LT radiator kW 1.86 2.04 2.47 3.70 4.38 5.22
+7°C/+55°C - Radiator kW 1.79 1.79 1.94 2.86 3.25 4.01
-7°C/+55°C - Radiator kW 2.20 2.33 3.34 4.15 4.45 5.20
Coecient of Performance (COP) (+7°C/+35°C) 4.52 4.26 4.08 4.02 4.00 3.68
Electrical specications
Electrical voltage (50 Hz) V 230
Maximum current for appliance A 11 12.5 17.5 18.5 22 25
Nominal current A 4.5 6.3 8.1 10.9 11.4 14.2
Maximum current of the Heating system electrical backup (option) A 13.05 / 26.1
Power of the Heating system electrical backup (option) kW 6 kW
Fan actual power consumption W 49 49 49 100 2 x 100 2 x 100
Circulation pump actual power consumption W 24 24 24 24 39.5 39.5
Maximum power consumed by the outdoor unit W 2530 2875 4025 4255 5060 5750
Rate according to EN14825 0.0100 0.0070 0.0057 0.0044 0.0038 0.0029
Hydraulic Circuit
Maximum operating pressure MPa (bar) 0.3 (3)
Flow rate of the hydraulic circuit for 4°C<Δt<8°C
(rated conditions) minimum / maximum
l/h 490/980 650/1300 810/1620 1080/2160 1380/2760 1720/3450
Miscellaneous
Weight of outdoor unit Kg 41 41 42 60 92 92
Noise level
1
at 1 metre (hydraulic unit) dB (A) 39
Sound power level in accordance with EN 12102
2
(hydraulic unit) dB (A) 46
Noise level
1
at 1 metre (outdoor unit) dB (A) 41 41 47 47 47 48
Sound power level in accordance with EN 12102
2
(outdoor unit) dB (A) 63 63 69 69 69 70
Weight of hydraulic unit (empty / full of water) Kg 42 / 58
Hydraulic unit water capacity l 16
Heating system operating limits
Outdoor temperature min/max °C -20 / +35 -20 / +35 -20 / +35 -20 / +35 -25 / +35 -25 / +35
Underoor heating system max. heating ow water temperature °C 45
LT radiator max. heating ow water temperature °C 55 55 55 55 55 55
Min. ow water temperature °C 8
Refrigeration circuit
Gas pipe diameters Inches 1/2 1/2 5/8 5/8 5/8 5/8
Liquid Piping Diameters Inches 1/4 1/4 1/4 3/8 3/8 3/8
Factory ll of refrigerant R410A
3
g 1100 1100 1400 1800 2500 2500
Maximum operating pressure MPa (bar) 4.15 (41.5)
Minimum / Maximum length of pipes
4
m 5 /15 5 /15 5 /15 5 /15 5 /15 5 /15
Maximum length of pipes
5
/ Maximum level dierence m 30 / 20 30 / 20 30 / 20 30 / 20 20 / 15 20 / 15
1
Hydraulic unit: Sound pressure level at (x) m from the appliance, 1.5m o the ground,
open eld directionality 2 / Outdoor unit : Sound pressure level at (x) m from the device,
halfway between the ground and top of the outdoor unit, open eld directionality 2.
2
The sound power level is a laboratory measurement of the emitted sound
power. It does not correspond to a measurement of the perceived sound
power.
3
Refrigerant R410A as per NF EN 378.1 standard.
4
Filling with refrigerant R410A is done at the factory.
5
Taking into account a possible additional ll of refrigerant R410A
(see "Additional lling", page 31).
Installation manual "1872 - EN" - 7 -
Alféa Extensa A.I. Heat Pump