Model name Alféa Extensa A.I. 5 6 8 10 13 16
Rated heating performances (outdoor temp. / ow temp.)
Heat output
+7°C/+35°C - Underoor heating system kW 4.50 6.00 7.50 10.00 14.01 16.06
-7°C/+35°C - Underoor heating system kW 4.10 4.60 5.70 7.40 9.45 12.93
+7°C/+45°C - LT radiator kW 4.50 5.10 6.20 8.27 10.43 13.60
-7°C/+45°C - LT radiator kW 4.10 4.45 5.05 7.40 9.25 11.20
+7°C/+55°C - Radiator kW 4.50 4.50 5.00 7.00 7.84 10.03
-7°C/+55°C - Radiator kW 3.70 3.85 5.20 7.00 7.29 8.65
Power consumption
+7°C/+35°C - Underoor heating system kW 1.00 1.41 1.84 2.49 3.50 4.37
-7°C/+35°C - Underoor heating system kW 1.47 1.74 2.23 2.97 3.92 5.32
+7°C/+45°C - LT radiator kW 1.31 1.50 1.87 2.53 3.19 4.38
-7°C/+45°C - LT radiator kW 1.86 2.04 2.47 3.70 4.38 5.22
+7°C/+55°C - Radiator kW 1.79 1.79 1.94 2.86 3.25 4.01
-7°C/+55°C - Radiator kW 2.20 2.33 3.34 4.15 4.45 5.20
Coe󰀩cient of Performance (COP) (+7°C/+35°C) 4.52 4.26 4.08 4.02 4.00 3.68
Electrical specications
Electrical voltage (50 Hz) V 230
Maximum current for appliance A 11 12.5 17.5 18.5 22 25
Nominal current A 4.5 6.3 8.1 10.9 11.4 14.2
Maximum current of the Heating system electrical backup (option) A 13.05 / 26.1
Power of the Heating system electrical backup (option) kW 6 kW
Fan actual power consumption W 49 49 49 100 2 x 100 2 x 100
Circulation pump actual power consumption W 24 24 24 24 39.5 39.5
Maximum power consumed by the outdoor unit W 2530 2875 4025 4255 5060 5750
Rate according to EN14825 0.0100 0.0070 0.0057 0.0044 0.0038 0.0029
Hydraulic Circuit
Maximum operating pressure MPa (bar) 0.3 (3)
Flow rate of the hydraulic circuit for 4°C<Δt<8°C
(rated conditions) minimum / maximum
l/h 490/980 650/1300 810/1620 1080/2160 1380/2760 1720/3450
Miscellaneous
Weight of outdoor unit Kg 41 41 42 60 92 92
Noise level
1
at 1 metre (hydraulic unit) dB (A) 39
Sound power level in accordance with EN 12102
2
(hydraulic unit) dB (A) 46
Noise level
1
at 1 metre (outdoor unit) dB (A) 41 41 47 47 47 48
Sound power level in accordance with EN 12102
2
(outdoor unit) dB (A) 63 63 69 69 69 70
Weight of hydraulic unit (empty / full of water) Kg 42 / 58
Hydraulic unit water capacity l 16
Heating system operating limits
Outdoor temperature min/max °C -20 / +35 -20 / +35 -20 / +35 -20 / +35 -25 / +35 -25 / +35
Underoor heating system max. heating ow water temperature °C 45
LT radiator max. heating ow water temperature °C 55 55 55 55 55 55
Min. ow water temperature °C 8
Refrigeration circuit
Gas pipe diameters Inches 1/2 1/2 5/8 5/8 5/8 5/8
Liquid Piping Diameters Inches 1/4 1/4 1/4 3/8 3/8 3/8
Factory ll of refrigerant R410A
3
g 1100 1100 1400 1800 2500 2500
Maximum operating pressure MPa (bar) 4.15 (41.5)
Minimum / Maximum length of pipes
4
m 5 /15 5 /15 5 /15 5 /15 5 /15 5 /15
Maximum length of pipes
5
/ Maximum level di󰀨erence m 30 / 20 30 / 20 30 / 20 30 / 20 20 / 15 20 / 15
1
Hydraulic unit: Sound pressure level at (x) m from the appliance, 1.5m o󰀨 the ground,
open eld directionality 2 / Outdoor unit : Sound pressure level at (x) m from the device,
halfway between the ground and top of the outdoor unit, open eld directionality 2.
2
The sound power level is a laboratory measurement of the emitted sound
power. It does not correspond to a measurement of the perceived sound
power.
3
Refrigerant R410A as per NF EN 378.1 standard.
4
Filling with refrigerant R410A is done at the factory.
5
Taking into account a possible additional ll of refrigerant R410A
(see "Additional lling", page 31).
Installation manual "1872 - EN" - 7 -
Alféa Extensa A.I. Heat Pump