Step Action
1 Install the compressor, see the sections Dimension drawing, Installation proposal and
Electric cable size.
2 Affix the sticker, giving brief operating instructions, next to the control panel.
Stick labels near the control panel to warn the operator that:
•
the compressor may start automatically after a voltage failure
•
the compressor is automatically started and stopped
•
the compressor may be remotely controlled
3 A number of VCI (Volatile Corrosion Inhibitor) plates are provided inside the bodywork to
protect the compressor against corrosion. Remove the plates.
4 Remove filler plugs (1).
On GA90 up to GA250 and GA315 60 Hz and GR110 up to GR200, pour approx. 1 l (0.26
US gal/0.22 Imp gal ) of oil into the compressor elements.
Refit the plugs.
5 Check that the compressor is filled with oil; the pointer of the oil level indicator should be
in the green range (see the section Oil change).
Protection during transport
Transport fixtures for GA 90 up to GA 160