MT Focus 6000 EN Installation
© Atlas Copco Industrial Technique AB - 9839 0470 01
7
Installation
Installation requirements
Connecting accessories
If the sum of all +24V IO loads exceeds 400 mA - use an external +24 V
source.
The internal 24 V supply can be loaded with max 1300 mA. This supply is
used for both the vacuum pump and the +24V IO.
DIGITAL I/O
The digital I/O is a configurable 26-pole D-sub socket connector for digital in-
put and output signals.
Use a 26-pole D-sub pin plug.
Voltage range 11-30 VDC (logic 1)
0-5 VDC (logic 0)
Input resistance >5 kΩ
Output resistance 23-35 Ω
Output current protection 120 mA max. peak/continuous current, over current
protected.
If the max. current is exceeded, the output voltage will switch off. This can
be resolved by switching the output off and on again.
Pin I/O
1 +24V IO
2 DO COMMON 0-3
3 DO COMMON 4-7
4 DO 0
5 DO 1
6 DO 2
7 DO 3
8 DO 4
9 DO 5
10 DO 6
11 DO 7
12 DI 0
13 DI 1
14 DI 2