Event Event Text Acknow- Explanation
Code ledge
E000-E099: Rundown errors
E003 Incorrect programming - Check that there is socket movement in
the second stage
E100-E199: Event-related errors
E102 Rundown prohibited due - This error code is displayed after a NOK
tightening to Lock on Reject when the
function Lock on Reject is activated.
In thiscase the tool is disabled, the tool
can be unlocked with a digital input or
with the tool ring.
E103 Tool locked by digital
input
- The tool is locked via the digital input
E107 Rundown prohibited
due to
Line Control, batch not
enabled
- A job using Line Control is selected.
The job does not start until
Line Control Start signal is received.
E112 Rehit -
Event code Group Description
E001-E099 0 Rundown failures
E100-E199 1 Event-related errors
E200-E299 2 User input events
E300-E399 3 Statistical events
E400-E499 4 Communication events
E500-E599 5 Hardware events TOOL
E600-E699 6 Hardware events
DC3000/MC3000
E700-E799 7 Hardware events
E800-E899 8 Software events
E900-E999 9 Events MMI3000
EVENT CODES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 4000 Graph and is the answer not in the manual?

Atlas Copco Power Focus 4000 Graph Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 4000 Graph
CategoryController
LanguageEnglish

Related product manuals