28
E152 PF locked in job mode - This error appears when in a forced
cell job an attempt is made to tighten
with a controller which is not currently
active or when a controller has perfor-
med all tightenings.
E153 Not Ok to select
new job
- A job is currently running, it is not pos-
sible to select a new job until the fi rst
is fi nished in some way (completed
or aborted). This message is also
displayed if a job is selected on a job
member.
E154 Remote job running - When running a Cell Job, this is displayed
by the job members when a cell job is
selected on the job master.
E155 Remote job aborted - When running a Cell Job, This is displayed
by the job members when a cell job is
aborted.
E156 Job members lost - When running a Cell Job, this is displayed
by the master when it has lost contact
with one of its job members.
E157 Job reference lost - When running a Cell Job, this is displayed
by the job members when they have lost
contact with their Job Master.
E158 Invalid Job ID - When the selected job does not exist.
E159 No Pset In Selected Job - When the selected job does not contain
any Pset.
E160 Job select source not
valid
- Attempt to select a Job with the wrong
input source.
E161 Line Control Alert 1 - The line control has been activated,
and the fi rst control alert limit has been
reached.
E162 Line Control Alert 2 - The line control has been activated, and
the second control alert limit has been
reached.
E166 Job aborted A running job has been aborted
E167 Max coherent NOK
tightenings reached
The pre-set no. of successive NOK
tightenings was reached. Unlock via
digital input.
E175 Confi guration will be
erased at next reboot
Due to changed memory setup. Valid
for both PF and RBU.
E176 IPM memory needed Not possible to confi gure without IPM
memory