29
E177 Functionality not in
RBU
The user is trying to employ functiona-
lity not enabled in this RBU
E178 Memory allocation
error
The user is trying to allocate more
memory than is available
E179 Totally confi gurable
memory needed
Function not possible without ”totally
confi gurable memory”
E180 Euchner Ident System
only supports Siemens
3964R protocol
- The protocol settings for the serial COM
port 1 is not set to 3964R, it is not pos-
sible to use the Euchner Ident System
with this confi guration.
E181 Not possible to read
ID card
- When running a Cell Job, this is displayed
by the job members when a cell job is
aborted.
E190 Wrong ST scan source Attempt to scan from wrong source
E191 ST scanner over-heated The ST scanner has exceeded its highest
allowed value
E200-E299: User input error
E206 Pset number invalid - An attempt was made to do a tightening
with the wrong Pset within a job.
E207 Wrong Pset Select
Source
- Attempt to select Pset from a source not
specifi ed in the Cset.
E208 Not Ok to select new
Pset
- It is not allowed to select new Pset when
the already selected Pset is auto selected
by Job.
E211 Wrong identifi er input
source
Wrong input source for identifi er string
E212 Pset or Multistage
stored
This event is displayed whenever a Pset
or Multistage is stored or restored
E220 Fastener broken Displayed if fastener (screw or nut) break
during yield control
E221 Too few samples for
yield control
Too few samples for mean tq calculation
in yield algorithm. Parameter No degrees
too small or speed too high during yield
control
E233 Final target range error - This error code is displayed when an
attempt is made to tighten with a fi nal
target out of range (larger than tool max
torque or 9999).
E234 Start fi nal angle range
error
- This error code is displayed when an
attempt is made to tighten with a start
fi nal angle out of range.