35
E460 FieldBus Type Mailbox
Message Fault
-
E461 FieldBus Type Gen
Com Fault
-
E462 FieldBus Mailbox Mes-
sage Fault
-
E463 FieldBus Gen Com Fault -
E464 FieldBus Hardware
Fault
Yes The FieldBus module is broken and
has to be replaced.
E465 FieldBus Dip switch Error - The software tries to confi gure the value
of node address or baudrate but the
address switch on the FieldBus module
is not in the right position to enable soft-
ware setting. Set switches in the right
position, then turn on the power.
E466 FieldBus Offl ine - The FieldBus went from Online to
Offl ine. This is just a warning.
E467 FieldBus Confi guration
Fault
-
E468 FieldBus Hardware
Mismatch
- The FieldBus module installed in PF 3000
is not the same FieldBus type as confi gu-
red with TTPF. Change FieldBus module
or confi guration to get a match.
E469 FieldBus Init Error - RBU did not respond to command
from PF.
E470 FieldBus PCP error -
E471 Fieldbus claim area fai-
led, lost one message
One packet lost.
E472 Fieldbus release area
timeout
Release area command timed out.
E473 Fieldbus communica-
tion buffer alarm
Communication buffer full. Decrease
fi eldbus update timer.
E474 Fieldbus monitor buffer
alarm
Fieldbus monitor buffer full. Turn off
fi eldbus monitor mode.
E475 Fieldbus PsetID mis-
match selector lifted
socket
Fieldbus selected Pset does not fi le
the lifted socket.
E480 Channel ID not valid Yes The channel ID confi gured is not within
the limits permitted. The channel ID
must confi gured between 1 and 20.