E824
Cycle abort timeout - No tightening result was received
from the drive before the Cycle abort
timeout. The Cycle Abort timer is
confi gurable in the Pset.
E831
Autoset wrong angle -
Autoset could not be executed,
the angle results of the tightening
performed were null.
E833 Autoset tight NOK
result
- The Autoset could not be executed,
four NOK tightenings were performed.
E834 Autoset rejected Pset
in CCW direction
- The Autoset was not allowed by the
PF3000 for this Pset because the Pset
was confi gured in the CCW direction.
Auto set is only permitted on CW Pset.
E840 Feature Not Available In
Software Revision
This error is displayed if an attempt is
made to run multistage with a bronze
version, or handle a Pset with a Pset
ID larger than the max number of Pset
(larger than 64 in a bronze version
or larger than 250 in a silver or gold
version).
E841 SW function Not Availa-
ble for this tool type
The software function is not availbale
for this tool type.
E851 Connection with Tools
Net server lost
- The connection with the ToolsNet ser-
ver was lost, the PF3000 is trying to
reconnect. The Tools Net server might
be down or it might be an Ethernet
cable problem.
E856 Router unreachable The router programmed in the confi -
guration setting could not be reached.
Check the network confi guration and
in particularly the sub net mask and
the default router.
E857 Reboot needed before
changes take effect
The confi guration changes will not take
effect before a system reboot.
E858 IP address already
in use
Yes The IP address of this PF3000 is
already in use by another system.
E859 IP address collision - Another system attempts to use the
same IP address as this PF3000.
E862 Ethernet overload Error The Ethernet driver of the PF3000 is swit-
ched off due to an overloaded network.
39

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 4000 Graph and is the answer not in the manual?

Atlas Copco Power Focus 4000 Graph Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 4000 Graph
CategoryController
LanguageEnglish

Related product manuals