This quick guide is based on the Power Focus W7.2 manual
E863
IP Port already in use Yes
An attempt was made to bind
a TCP or UDP socket to a port
already in use. For instance, a
customer protocol might be using
the same port as ToolsTalk.
E864
Ethernet echo detected - An Ethernet packet was discarded,
since its source MAC address was
equal to the PF’s own MAC address.
Notice that this message only occurs
once during runtime, even if several
such packets are detected. There is
most likely a problem in the network.
E870
Syncmember registra-
tion failure
- The sync member registration failed.
Two sync members can have the
same channel ID or one PF3000 with
a sync reference IP address is missing
in the sync list.
E871
Syncmaster confi gura-
tion failure
-
The master channel iD is not fi rst in
the sync list.
E872 Sync initialisation
failure
- The tightening synchronisation
initialisation failed. Check the CAN bus
cable, check that all the sync members
have the same active Pset, check the
external start bridge
E873 Synchrotork not yet
implemented
- Synchro tork not yet implemented,
check the sync confi guration.
E874 Sync members missing Only sync reference is defi ned in the
sync list.
E900-E999: Errors MMI3000
E901 MMI Start-up Error Yes Error in MMI detected.
END
40

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 4000 Graph and is the answer not in the manual?

Atlas Copco Power Focus 4000 Graph Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 4000 Graph
CategoryController
LanguageEnglish

Related product manuals