Circuit-breaker, 3ph., lower voltage (optional)
Number of poles 3 -
Thermal release It (thermal release is higher at 25°C) 1250 A -
Magnetic release Im 4 x In -
Fault current protection
Residual current release IDn 0.030-30 A 0.030-30 A
Insulation resistance 10-100 kOhm 10-100 kOhm
Outlet sockets (optional) domestic (1x)
2p + E
16 A/230 V
CEE form (1x)
3p + N + PE
16 A/400 V
CEE form (1x)
3p + N + PE
32 A/400 V
CEE form (1x)
3p + N + PE
63 A/400 V
CEE form (1x)
3p + N + PE
125 A/400 V
Unit Dimensions (LxWxH) 4800 x 1550 x 2300 mm 4800 x 1550 x 2300 mm
Weight net mass 5350 kg 5350 kg
Weight wet mass 6250 kg 6250 kg