- 94 -
Alternator Standard IEC34-1 IEC34-1
ISO 8528-3 ISO 8528-3
Make LEROY SUMMER LEROY SUMMER
Model LSA 47.2 M7 LSA 47.2 M7
Rated output, class H temperature rise 500 kVA 625 kVA
rating type acc. ISO 8528-3 “BR” 125/40°C “BR” 125/40°C
Degree of protection IP 23 IP 23
Insulation stator class H H
Insulation rotor class H H
Number of wires 12 12
Engine Standard ISO 3046 ISO 3046
ISO 8528-2 ISO 8528-2
Type Volvo TAD1641 GE TAD1641 GE
Rated net output 430 kW 485 kW
rating type acc. ISO 3046-7 ICXN ICXN
Coolant coolant coolant
Combustion system direct injection direct injection
Aspiration turbocharged turbocharged
intercooled intercooled
Number of cylinders 6 6
Swept volume 16.12 l 16.12 l
Speed governing electronic electronic
EMS 2 EMS 2
Capacity of oil sump 42 l 42 l
Capacity of cooling system 60 l 60 l
Electrical system 24 Vdc 24 Vdc
Emission compliance EU STAGE II EU STAGE II
Power circuit Circuit-breaker, 3ph.
Number of poles 4 4
Thermal release It (thermal release is higher at 25°C) 720 A 720 A
Magnetic release Im 4 x In 4 x In