SmartROC T45-10 3 Controls and Instruments
18
Drillstop
ProportionalFunctionforRightLeverinDrillMode
x Rotation
y Feed
A SectorAhasaproportionalfunctionforrotationandfeed.
HighPercussionandLowPercussionduringCollaringandFulldrilling
Deactivatesdrillingduringcollaring(lowpercussion,lowrotation,lowfeed).Doesnotdeacti
vateflushair.
Activatescollaringduringfulldrilling(lowpercussion,lowrotation,lowflushair,lowfeed).
Activatesfulldrillingduringcollaring(highpercussion,highrotation,highflushair,lowfeed).
Deactivatesdrillingduringfulldrilling(percussion,rotation,feed).Doesnotdeactivateflushair.