TPS Control EN User guide
© Atlas Copco Industrial Technique AB - 9836 5819 01
33
Sequence
Position
Service
System parameter
Parameter name Description Range/Values
Station number Identifier for the tightening system 0-255
Default: 0
Tool model Defines the type of tool used.
This parameter is only visible if the activation code for
air tools has been entered.
Electric/Air tool
Default: Electric
Position control No = TPS Control is used without a torque arm (TPS
Control is only used as counter)
Yes = TPS Control is used with a torque arm (counter
and position check)
No/Yes
Default: Yes
Special functions Determines whether advanced parameters will be visi-
ble in the display. Values set for the advanced param-
eters will still remain, even if this parameter is set to
OFF.
Off/On
Default: Off
Timed outputs Sets the length of the pulse for output signals in each
position that is defined as a pulse.
0.0 - 9.9
Default: 0.5
Job selection Specifies whether the job selection is controlled by a
barcode scanner, the keyboard or other external de-
vices.
Ext. Inputs, Keyboard, Barcode
Default: Keyboard
Sound signal Determines whether and for which result the built-in
beeper gives an acoustic signal.
Off, Signal OK, Signal NOK
Default: Signal NOK
RS-232 set up Sets the serial connection parameters (in a separate
submenu)
Display set up Sets the display parameters (in a separate submenu)
Enter password Determines whether a fixed password should be en-
tered in order to access the Setup Menu and Job Edit
functions. If the password function is enabled, enter
the following password in sequence upon request:
NOK - Reset - VAL - INFO - ESC - MENU - OK
Off, Single, Always
Default: Off
RS-232 set up
Parameter name Description Range/Values
C1:baudrate Defines the transmission speed for the first serial inter-
face
4800-115200
Default: 38400
C1:data bits Allows you to set the data byte length for the first serial
interface
7, 8
Default: 8
C1:parity Allows you to define the parity method for the first se-
rial interface
None, even, odd
Default: None
C1:character delay Defines a waiting period that occurs during transmis-
sion after each character (in ms)
0-20 ms
Default: 0
C1:line delay Defines a waiting period that occurs during transmis-
sion after each line (in ms)
0-99 ms
Default: 0
C2:baudrate Defines the transmission speed for the second serial
interface (Barcode Scanner)
4800-115200
Default: 9600