- 118 -
AFTER-COOLER
An integral after-cooler, with water separator (1), is
available to reduce the outlet air temperature to
ambient plus 10°C (18°F) and cut water content to a
mere 15%. This performance can be obtained under
optimal atmospheric conditions.
When an after-cooler is used in an application where
the temperature is critical the air outlet temperature
can be monitored by the compressor controller.
A warning can be set at a value between 0°C and
115°C (=default value) and a shut-down can be set at
a value between 0°C and 120°C (= default value). The
operator has authority to modify these values so the
process can be guarded and kept in a safe condition
under all circumstances.
See also table Fault codes on page 73.
The installation includes a by-pass over the after-
cooler. For applications that demand quality air, a fine
filtration unit (2) can be specified with the after-
cooler package. This will remove oil and particles
down to 0.01 mg/m
3
.
For purer, but not breathing, air, an active charcoal
filtration unit (3) can be specified with the after-
cooler package. This removes oil and oil vapour
content to 0.003 mg/m
3
.
REMOTE START
The remote start allows the user to start, stop the
compressor and switch to load/noload by radiosignal.
This is particularly comfortable when the compressor
can not be positioned directly at the job site because
of blocking by buildings or other obstacles.
(1)
(2)
(3)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco XRXS 607 and is the answer not in the manual?

Atlas Copco XRXS 607 Specifications

General IconGeneral
BrandAtlas Copco
ModelXRXS 607
CategoryAir Compressor
LanguageEnglish

Related product manuals