SETTINGS
For buttons to be used see “Control Panel”
Acknowledge an Alarm
If an alarm becomes active, for example a Low Fuel
Level Warning:
then this alarm can be acknowledged by pressing the
ENTER button. If the fuel level is still low, the view
will change to:
As soon as the fuel level is higher than the warning
level, the alarm icon will automatically disappear.
As long as there is an alarm icon in the middle of the
bottom part of the view, all active acknowledged / un-
acknowledged alarms can be seen by pressing the
ALARM VIEW button
Pressing the ALARM VIEW button again, will bring
you back to the Main View.
Set Clock
Press the SETTINGS VIEW button
scroll to ‘1000 GENERAL SETTINGS’
press ENTER
scroll to ‘1290 DATE/TIME’
ENTER the Date/Time menu
scroll to the parameter you want to change
ENTER this parameter.
To change the ‘RTC Month’, scroll to the preferred
month and press ENTER.
To change any other RTC setting, the red figure is
editable.
Scroll up/down and press ENTER to change. Use left/
right to shift between editable figures.
Now press BACK until you’re back in the Main View
(or in the menu you require).
Set Language
Press the SETTINGS VIEW button.
scroll to ‘1000 GENERAL SETTINGS’
press ENTER
scroll to ‘1300 LANGUAGES’
ENTER the LANGUAGES menu,
ENTER the ‘SETTINGS’ parameter
scroll to the preferred language
press ENTER.
Now press BACK until you’re back in the Main View
(or in the menu you require).
Set Units
Press the SETTINGS VIEW button,
scroll to ‘1000 GENERAL SETTINGS’
press ENTER
scroll to the unit you would like to change:
‘1340 TEMPERATURE UNITS’
‘1350 PRESSURE UNITS’
‘1360 FUEL FLOW UNITS’
‘1370 AIR FLOW UNITS’
ENTER the preferred menu
ENTER the ‘SETTINGS’ parameter
scroll to the preferred setting
press ENTER.
Now press BACK until you’re back in the Main View
(or in the menu you require).
MAIN VIEW
LOADED
12.3
3000 FUEL LEVEL LOW WARNING
MAIN VIEW
LOADED
12.3
1300RPM 12.3bar9% 1381h

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco XRXS 607 and is the answer not in the manual?

Atlas Copco XRXS 607 Specifications

General IconGeneral
BrandAtlas Copco
ModelXRXS 607
CategoryAir Compressor
LanguageEnglish

Related product manuals