Test Run 26
BP8000
2. Adjust safety cable
Lift the carriage and lock at the same height, strain the Safety Cable and then
release a little, and then tighten the cable locking nuts. Make sure the safety
device functions properly.
3. Adjust the lower speed (Only for ATLAS power unit)
You can adjust the lowering speed of the lift if needed. Loosen the locking nut on
the Throttle Valve and turn the Throttle Valve clockwise to decrease the lowering
speed or counterclockwise to increase the lowering speed. Do not forget to
tighten the locking nut after the lowering speed adjustment has been done.
Note: This procedure must be done with a load on the lift.
Fig. 30
Clockwise to
decrease the
down speed
Throttle Valve
Fixing Nut
Counter-clockwise
to increase the
down speed