Installation Requirements 7
BP8000
Speci cations Of Concrete
Concrete must be in compliance to the speci cations below.
Failure To Do So May Result In Personal Injury or Property Damage.
1. Concrete must have a thickness of 4 inches minimum and without reinforcing
steel bars, and must be completely cured before the lift installation.
2. Concrete must be in good condition and must have a test strength 3,000 psi
(210kg/cm²) minimum.
3. Floors must be level and no cracks.
Fig. 4
Power Supply
The capacity of power must be 3 HP minimum. The electrical wire must
be a minimum of 10 gauge.