Service conditions
AUMA silver-grey (similar to RAL 7037)Standard:Colour
Available colours on requestOption:
AUMA multi-turn actuators meet or exceed the lifetime requirements of EN 15714-2. Detailed information
can be provided on request.
Lifetime
Further information
Electromagnetic Compatibility (EMC): (2014/30/EU)
Low Voltage Directive: (2014/35/EU)
Machinery Directive: (2006/42/EC)
EU Directives
Technical data for limit and torque switches
2 x 10
6
startsMechanical lifetime
Silver plated contacts:
30 V AC/DCU min.
250 V AC/DCU max.
20 mAI min.
5 A at 250 V ACAC-15:Rated voltage/current
0.15 A at 250 V DCDC-13:
Gold plated contacts
5 VU min.
30 VU max.
4 mAI min.
400 mAI max.
Technical data for blinker transmitter
10
7
startsMechanical life-
time
Silver plated contacts:
10 V AC/DCU min.
250 V AC/DCU max.
5 A at 250 V (resistive load)
5 A at 250 V (inductive load, cos phi 0.8)
I max. AC current
0.25 A at 250 V (resistive load)I max. DC current